18
en | Configuration
GPRS/GSM IP Communicator
F01U163066 | 01 | 2010.05
Installation and Operation Guide
Bosch Security Systems, Inc.
Refer to
Section Multiple SMS Messages (for Messages Longer than 160 Characters), page 19
for
instructions for sending a multiple SMS configuration.
The templates below contain only the essential configuration IDs. For additional configuration
IDs, refer to
.
Refer to
for information about the modes allowed for your control panel.
IP over GPRS Mode
Table 4.2
IP over GPRS Mode and Dual Wireless Mode SMS Configuration
NOTICE!
Separate each ID or value pair with a line feed (<LF>), a carriage return (<CR> or
<
ENTER>), or a semi-colon <;>. Due to phone and carrier differences, Bosch recommends
using semi-colons to create and send SMS messages. For example,
%1;1=4020G;10=Airnet1;14=88;17=2;!
. To allow spanning of configuration across multiple
messages, each SMS starts with the sequence number followed by the command line
separator.
Any of these characters is acceptable to separate command lines. Refer to your cellular
phone’s documentation for available characters.
ID
Description
Sample SMS
%1
SMS sequence number 1
1
1=
Current password (4 to 15 characters);
default = 4020G
10=
GPRS access point name (APN); 1 to 63 characters
14=
–
88 (GV2 Series or GV3 Series)
–
92 (GV3 Series)
–
134
(default)
–
250 (FPD-7024)
17=
Communication path:
–
1 = Both
(default)
–
2 = IP over GPRS
–
3 = PSTN (Contact ID) over GSM
!
End of configuration
1
The % symbol starts the SMS configuration message content. Any data before the % symbol is discarded.
The % symbol is followed directly by the sequence number of the message (1 to 3).
%1
1=4020G
10=basic.m2m
14=88
17=2
!
Содержание ITS-DX4020-G
Страница 1: ...GPRS GSM IP Communicator Conettix ITS DX4020 G en Installation and Operation Guide ...
Страница 2: ......
Страница 51: ......