8.8 Viewing system information
Installer settings: System info
Shows a variety of system information:
•
Installation date
(automatically activated on
commissioning)
•
Boiler part number
(fixed setting from boiler)
•
Boiler date of manufacture
(fixed setting
from boiler)
•
Controller part number and model
(fixed
factory setting)
•
Controller date of manufacture
(fixed factory
setting)
•
Controller software version
(fixed factory
setting)
Menu structure
Æ
page 64.
8.9 Slab drying function
Installer settings: Slab drying
The slab drying function allows fresh slab on
radiant floor heating to be dried in accordance
with the slab manufacturer's instructions. All
mixed heating circuits are heated up equally.
Menu: Slab drying
•
Cancel slab drying
: If the slab drying function
is activated, the function can be switched off
with
Yes
.
•
Maximum heating supply temperature
: Enter
the maximum flow temperature (1) for the
slab drying function here.
•
Maintain max heating supply temp for
: Enter
the timescale (2) here of when the maximum
supply temperature should be maintained.
WARNING:
Risk of damaging or
destroying the slab.
B
With multi-circuit systems this
function can be used in
combination with a mixed
heating circuit.
B
Program slab drying function in
accordance with slab
manufacturer's instructions.
B
In spite of the slab drying
function, visit the system daily
and make the prescribed
reports.
DHW heating is not possible from
programming to completing the slab
drying function.