6 720 643 256 (2010/05)
Viewing information
|
55
US/CA
DWU1: High return valve
status
On | Off
Status of the valve DWU1, for return temperature
raising
Solar heating support
status
On | Off
Shows whether solar energy is currently available for
the heating network.
collector field 2
–
Menu for the system part 2nd collector field
TA: Temperature of
collector field 2
189.4 °F (87.4 °C)
Temperature measured by collector temperature
sensor (TA) in 2nd collector field.
PA: Collector field 2
pump status
Running | Off
Switch status of solar pump (SP) for the 2nd
collector field.
Collector field 2 shut
down
Yes | No
Shows whether there has been an emergency
shutdown of the solar pump (PA) due to the
collectors overheating (TA).
PA: Coll field 2 pump run
time
5370hr
Number of hours of duty of the solar pump (SP) for
the 2nd collector field since commissioning.
Reload system
–
Menu for the system part drinking water reload.
TB: Temp at top of tank B 137.6 °F (58.7 °C)
Temperature measured at top tank temperature
sensor (TB) in the solar tank B.
PB: DHW reload pump
status
Running | Off
Switch state of the drinking water reload pump
Tank B status
Fully charged | Partially
charged
Load status tank B.
High/low priority
–
Menu for the system part low/high priority tank
system.
TC: Temp at bottom of
tank C
140.6 °F (60.3 °C)
Temperature measured at bottom tank temperature
sensor (TC) in the solar tank C.
Currently charging
Tank C | Solar tank
Shows which tank is currently being charged (the
solar tank or tank C).
PC: Solar pump status
On | Off
Status of the second solar pump (PC) in the high/
low priority system.
DWUC: Hi/lo priority
valve status
On | Off
Status of the high/low valve (DWUC) in the high/low
priority system.
Tank C status
Fully charged | Partially
charged
Charge status tank C.
Priority tank charging
test
Running | Off
Status of the test mode for charging the priority tank
Next priority tank
charging test at
5:30pm (17:30)
Time for the next test for charging the priority tank.
Ext. heat exchanger
–
Menu for the system part external solar heat
exchanger.
TD: External heat
exchanger temp
211.6 °F (99.8 °C)
Temperature measured on the temperature sensor
(TD), external heat exchanger
PD: Secondary circuit
pump status
Running | Off
Switch state of the high/low priority valve between
the external heat exchanger and the tank.
Menu structure INFO
Display (example)
Description