6 720 643 256 (2010/05)
30
|
Operation
US/CA
5.4 Changing the specified room
temperature
5.4.1 Permanently changing the specified
room temperature
The following temperatures are stored as the
factory settings for the specified room
temperature:
•
Operating mode
Comfort
: 70 °F (21 °C)
•
Operating mode
Economy
:
60 °F
(15 °C)
•
Operating mode
Frost
: 42 °F (5 °C)
The heating controls regulate the heating system
so that actual room temperature is kept as close
as possible to the specified temperature for the
set operating mode (in
mode as
determined by the active heating program and
the time of day). You can change these set values
independently for each heating circuit.
If you wish to permanently alter the specified
room temperature settings, proceed as follows:
B
Call up menu:
Heating > Parameter > Heating
circuit 1…2 > Heating levels
.
B
Set values for each operating mode.
5.4.2 Changing the specified room
temperature for a limited period
This function is only available if the heating
circuit is not regulated via remote control FB 100.
B
Set the desired room temperature using the
dial .
While you are changing the set room
temperature the display shows the desired
room temperature or a bar
1)
, which shows a
set change.
–
If the mode selector is set to
:
The new temperature applies until the next
switch point.
–
If the mode selector is set to / / :
The new temperature applies until the
mode selector position is changed.
The controls provide the option of
setting the desired room
temperature for the operating mode
concerned. This temperature entry
is not the actual room temperature.
This is an orientation value that
influences the required supply
temperature for the heating zone.
1) The bar is shown if the heating controls
FW 200 are installed in the boiler facia or
room influence is not active. For setting
the room influence for installers, see
page 70