6 720 643 256 (2010/05)
48
|
MAIN MENU settings
US/CA
6.3.6 Thermal disinfection of domestic hot
water
Menu: Domestic hot water > Thermal
disinfection
This menu is only active if your hot water is
provided by a hot water tank. We recommend
that you carry out thermal disinfection at regular
intervals. For larger hot water systems, there may
be a legal requirement for thermal disinfection.
If you have a combi boiler, please refer to the
guidance in the boiler documentation.
•
Operating mode
:
–
Auto
: Thermal disinfection starts
automatically according to the set starting
conditions. The thermal disinfection can be
switched on and cancelled manually.
–
Manual
: Thermal disinfection can be
started from
Operating status
.
•
Operating status
:
–
Not running
: No thermal disinfection in
progress at present. Once-only thermal
disinfection can be started by selecting
Start now
.
–
Running
: Thermal disinfection currently in
progress. Thermal disinfection can be
stopped by selecting
Stop
.
If
Solar sys option E Thermal disinfection
is switched on (
Æ
Section 8.4 on page 72)
and thermal disinfection is stopped by
selecting
Stop
, a fault is indicated for 5
minutes if the disinfection temperature in
the solar tank has not been reached (Fault
54,
Æ
Section 9.1 starting on page 86).
•
Time
: Starting time for automatic thermal
disinfection.
•
Time interval
: Period until next starting time
for automatic thermal disinfection.
For menu structure and adjustment ranges
Æ
page 35.
WARNING:
RISK OF SCALDING
Hot water can cause scalding.
B
Only carry out thermal
disinfection at times when the
system is not normally in use.
B
Inform occupants of the building
of the danger of scalding and
always monitor the thermal
disinfection process.
If you want to use automatic
thermal disinfection (e.g. once a
week), proceed as follows:
B
Set the required time interval
(e.g. 7d, i.e. 7 days).
B
Set the required start time (e.g.
10:00pm (22:00)).
B
Set the operating mode
to Auto
on the day
on which you want
thermal disinfection to take
place.
Содержание FW 200