Check if the resistance of 4-way valve coil is
correct.
Check if there is AC voltage applied on CN4 of
ODU PWB just before the compressor starts.
Check if the 4-way-valve can switch normally by
confirming the operating sound.
Measure if the pressure of refrigerant is proper
by gauge manifold for checking the refrigerant
volume.