4-20
Climate Class 6100i / 6000i / 8100i / 8000i
Problem
symptom
Outdoor
unit
indica-
tion
(LED1)
Malfunction
No.*
Content of diagnosis
Check point
Action
Main
Sub
Main
Sub
Indoor unit
operates.
Outdoor
unit
does not
operate.
Lighting
or
OFF
17
0
Wiring
between
units
Serial opencircuit 1) Check the wires between
units.
1) Connect stable power
supply. Correct the
wiring.
2) Check voltage between
N and 1 the indoor/out-
door unit terminal boards.
2) Replace the outdoor
unit control PWB as-
sembly.
3) Check the outdoor unit
fuse.
3) Replace the fuse/ out-
door unit control PWB
assembly.
4) Check voltages of
15V-0V,12V-0V and 5V-
0V on the PWB.
15V-0V :15V
12V-0V :12V
5V-0V :5V
Check resistance be-
tween IPM terminals.
4) Replace the outdoor
unit control PWB as-
sembly.
5) No abnormality found
in above inspections (1)
through (4).
5) Replace the outdoor
unit control PWB board.
Indoor unit
operates.
Outdoor
unit
does not
operate.
Lighting
or
OFF
18
0
Wiring
between
units
Serial short-cir-
cuit
1) Check the wiring be-
tween units.
1) Correct the wiring.
Indoor and
outdoor
units
do not
operate.
1
Serial erroneous
wiring
1) Check the wiring be-
tween units.
1) Correct the wiring.
Indoor and
outdoor
units do
not
operate.
Normal
blinking
or
OFF
19
0
Indoor unit
fan
Indoor unit fan
error
1) Check the indoor fan
motor for proper rotating
operation. (Check fan
lock.)
1) Replace the indoor fan
motor.
2) Check the lead wire of
the indoor fan motor for
open-circuit.
2) Replace the indoor fan
motor.
3) Check connector of the
indoor unit fan motor for
secure installation
3) Correct the installation
of the indoor fan motor
connector.
4) No abnormality found
in above inspections (1)
through (3).
4) Replace the indoorunit
control PWB
Indoor and
outdoor
units do
not
operate.
Normal
blinking
or OFF
20
0
Indoor unit
control PWB
EEPROM data
error
1) (EEPROM read data
error)
1) Replace the indoor unit
control PWB
Содержание CLC6001i 25 E
Страница 7: ...1 6 Climate Class 6100i 6000i 8100i 8000i For CLC8101i 65 HE CLC8001i 25 E CLC8001i 35 E models ...
Страница 69: ...2 Climate Class 6100i 6000i 8100i 8000i 6 1 6 3 6 4 6 2 ...
Страница 77: ...10 Climate Class 6100i 6000i 8100i 8000i 6 1 6 3 6 4 6 2 ...
Страница 87: ...20 Climate Class 6100i 6000i 8100i 8000i 7 28 Reverse Value Ass y ...
Страница 88: ...21 Climate Class 6100i 6000i 8100i 8000i Expansion Value Ass y ...