Climate Class 6100i / 6000i / 8100i / 8000i
Air conditioner stopped with error 6
when more than 1 second after the
compressor started operating
Check if the power supply is fluctuant or has
momentary power failure.
Check if the air filter and
heat exchanger of IDU
has been blocked by
dust etc.
Check if the ODU air
outlet has been blocked.
Check if the ODU fan
motor operates
normally.
Check whether can
operate normally by
using another ODU fan
motor.
Check if the IDU lover
operates normally.
Check if the IDU fan
operates normally.
Check if the ODU
expansion valve
operates normally.
Check if IPM is floating from the heat sink.
Heating mode
Cooling mode
Ensure the air flow
from air outlet not
be blocked.
Connect air conditioner to stable power
source.