4-10
Climate Class 6100i / 6000i / 8100i / 8000i
6.Motion sensor trouble-shooting
! CAUTION !
• Sometimes, the buzzer sound is not stable for 3 minutes at just after pluging the power supply.
• Sometimes, the buzzer sound lags behind movement.
Press the AUX bu
tt
on.
The air condi
ti
oner starts opera
ti
on.
Press the display bu
tt
on on the remote controller
and check opera
ti
onLED lamp get dark.
The buzzer sounds if
someone move in
front of the sensor.
The Buzzer doesn't
sound if anyone
don't move in front
of the sensor.
YES
YES
NO
NO
OK.
Swap the Mo
ti
on Sensor Board.
YES
OK.
NO
A
ft
er that Press the AUX bu
tt
on for 5 seconds.
Check Opera
ti
on LED lamps is blinking.
Have the
problem been
fi
xed?
Swap the Display Board.
Have the
problem been
fi
xed?
Swap the Control Board.
NO
YES
OK.