18
Installation
www.bora.com
Q
Q
The drawers and/or shelves in the floor unit must be
removable for maintenance and cleaning purposes.
Q
Q
A return flow aperture > 500 cm² is required in the kitchen
units for recirculation appliances (e.g. by shortening the
plinth boards or using suitable slatted plinths).
X
X
Make sure that the front area of the floor unit is
sufficiently ventilated.
INFO
A minimum opening cross section of 50 cm²
must be provided for ventilation on the front
side and in the false floor.
6.5.1 Installation dimensions
≥700
≥900
≥74
Fig. 6.8
PKA and PKAS device installation dimensions
6.5.2 Fitting the cooktop extractor
1
2
Fig. 6.9
Installing the cooktop extractor
[1]
Worktop cut-out
[2]
Cooktop extractor
X
X
Place the cooktop extractor [2] in the middle of the
relevant worktop cut-out [1].
X
X
Precisely position the cooktop extractor [2].
Cut-out dimensions when installing cooktops only or
cooktops and the cooktop extractor next to each other:
Cooktops/cooktop extractor
A in mm
B in mm
1/0
374
346
2/0
745
717
3/0
1116
1088
1/1
485
457
2/1
856
828
3/2
1338
1310
4/2
1709
1681
Tab. 6.3 Cut-out dimensions (tolerance ±2)
6.4.4 Optional cable protection
If cable protection (false floor) is planned below the
device, this must be fitted so it can be removed for
maintenance work. Sufficient ventilation or extraction
must be guaranteed.
>80
100
Fig. 6.7
Side view of cable protection
6.5 Installing the extraction system
INFO
Clearance of one millimetre should be planned
between the built-in appliances.
In combination with an adjacent PKIW1
induction wok cooktop, the plastic strip on the
side of the cooktop extractor must be carefully
removed for this.
INFO
A clearance of two millimetres should be
planned around the built-in appliances.
Q
Q
Cross bars on the kitchen unit in the area of the
worktop cut-out may need to be removed.