EN
27
Installation
www.bora.com
Fig. 6.40 Wrap the connection cable round the ferrite sleeve
three times
X
X
Wrap the connection cable around the ferrite sleeve
3 times to create the desired filter performance.
X
X
Ensure that the cable end protrudes at least 120 mm
from the sleeve.
X
X
Prepare the connection cable in accordance with the
prescribed stripping lengths.
6
5
3
2
1
4
9
UFH
35
120
20
Fig. 6.41 Stripping lengths and installation position for
connection cable
[1]
Stripped wire end
[2]
Insulated wire
[3]
Jacketed cable
[4]
Strain relief clamp
[5]
Cable feed snap-out element
[6]
Universal ferrite sleeve (UFH)
Q
Q
Please adhere to the maximum stripping length of
9 mm on the stripped wire end [1].
Q
Q
Please adhere to the maximum stripping length of
26 mm on the insulated wire [2].
Installing the external switch device
Depending on the type of switch device, connect the
connection cables to either the Home In or the Home Out
connection clamp.
X
X
Adhere to the connection diagram when connecting
Home In and Home Out.
1
2
4
3
Fig. 6.39 Open the universal control unit’s cover
[1]
Cover
[2]
Electronic unit
[3]
Base unit
[4]
Switch contact terminals
INFO
The electronic unit [2] can contain residual
charge. You must therefore be careful not to
touch the exposed contacts on the electronic
unit!
Preparing connection cables for external
switching equipment
Use connection cables of the following types and
manufacturers to connect external switchgear.
Contact
Connection cable
Home In
H03VV-F
2 x 0.5 mm²
Home Out
H03VVH2-F 2 x 0.75 mm²
Tab. 6.5 Connection cable
INFO
The connection cable is only intended for
internal use in buildings, private households,
kitchens or offices.
INFO
The overall length of the connection cable for
external switching equipment must not exceed
10 m!
For reasons of electromagnetic compatibility, all
connection cables from external switch devices must be
filtered with a ferrite sleeve. This is not included in the
scope of delivery.
X
X
Use the order code UFH (universal filter sleeve) to
order the filter sleeve from your specialist supplier or
contact BORA via the website at www.bora.com.