EN
31
Installation
www.bora.com
Selecting the filter unit
You can select the filter unit installed under menu option
C3
.
INFO
Selecting correctly is key to ensure the filter
timer is set to the service life of the activated
charcoal filter (recirculation mode only).
INFO
In the event of a power cut, the last setting
saved is shown for 2 minutes.
Setting
Filter system
Service life
C 3 0
Exhaust air
No filter timer required
C3 1
ULB1
200 h
C 3 2
ULB3 (factory setting)
400 h
C 3 3
ULBP
1000 h
Tab. 6.10 Selecting the filter unit
Operation with/without wall sleeve
In the
C5
menu option, you can select whether the
extraction system is operated with or without the
BORA 3box (UEBF) wall sleeve.
Setting
Mode
C 5 0
Operation with wall sleeve
C5 1
Operation without wall sleeve
Tab. 6.11 Operation with or without wall sleeve
Manual operation of cover flap motors
You can open or close the cover flap manually in the
menu option
C6
.
Setting
Function
C 6 0
Exit sub-menu
C6 1
Opening the cover flap
C 6 2
Closing the cover flap
Tab. 6.12 Manual operation of cover flap motors
6.12.3 Changing the setting
X
X
Turn the knob ring clockwise to increase the value.
X
X
Turn the knob ring anticlockwise to decrease the value.
X
X
Press the touch surface on the control knob again for
1 second to confirm the new setting. The value is saved
and a beep sounds. The previously selected menu
option is shown again on the control knob display.
Setting the volume of the warning beep
Once you have confirmed menu option
C0
, you can set
the volume of the warning beep.
Setting
Warning beep volume
C 00
100% (max. volume)
Factory setting
C0 1
10% (min. volume)
C 02
20%
C 03
30%
C 04
40%
C 05
50%
C 06
60%
C 07
70%
C 08
80%
C 09
90%
Tab. 6.7 Warning beep volume
Select mode
When you have confirmed menu option
C 1
, you can select
the operating mode.
Setting
Mode
C 10
Normal operating mode
Factory setting
C 1 1
Demo mode
Tab. 6.8 Operating modes
INFO
In demo mode, all the control knob functions are
active and the electric cover flap and the fan work.
Demo mode is used, for example, for exhibitions.
Adjust the speed of the cover flap motor
You can adjust the speed of the cover flap motor under
menu option
C2
.
Setting
Speed of cover flap
C 2 0
100% (fastest)
C2 1
10% (slowest)
C 2 2
20%
C 2 3
30%
C 2 4
40%
C 2 5
50%
C 2 6
60%
Factory setting
C 2 7
70%
C 2 8
80%
C 2 9
90%
Tab. 6.9 Speed of cover flap