EN
22
Installation
www.bora.com
3
2
1
Fig. 6.25 Remove the holding plate
[1]
Ducting piece adapter
[2]
Holding plate
[3]
Bent ducting piece
X
X
Undo the Torx screw (size 10) securing the holding
plate [2] to the angled ducting piece [3].
X
X
Undo the 2 Torx screws (size 10) securing the holding
plate [2] to the ducting piece adapter [1].
X
X
Remove the holding plate [2].
2
1
Fig. 6.26 Remove the angled ducting piece
[1]
Angled ducting piece
[2]
Ducting piece adapter
X
X
Release the angled ducting piece [1] from the ducting
piece adapter [2].
X
X
To do this, carefully disconnect the plug connection
using a flat screwdriver.
X
X
Remove the angled ducting piece [1].
X
X
If necessary, rotate the cover frame around 180° (see
Rotating the cover frame around 180°).
Fig. 6.24 Fitting the control knob
X
X
Pull off the knob ring [3].
X
X
Unscrew the universal nut [2].
X
X
Push the knob casing [1] through the hole in the panel
from the front.
X
X
Screw the universal nut [2] onto the knob casing [1]
from the rear and tighten a little.
X
X
Use the marking to align the knob casing [1] vertically
in the 12 o’clock position.
X
X
Tighten the universal nut [2].
X
X
Slot the knob ring [3] onto the knob casing [1] and
align it to the 12 o’clock position.
6.7 PKA planning options
INFO
With the PKA cooktop extractor, you have the
option of configuring the airflow either to the
left or the right to suit your requirements.
INFO
The pre-fitted angled ducting piece or straight
ducting piece (supplied) can feed the airflow
either in a 90° angle to the rear or straight out
to the side.
INFO
If using the straight ducting piece, an
additional EFD straight duct seal is required
(not supplied).
Q
Q
The cooktop extractor is supplied with a pre-fitted
angled ducting piece going to the right.
6.7.1 Airflow straight to the side
INFO
For straight airflow to the side, the installation
must be rotated around 180°. This means
the cover frame also needs to be rotated (see
rotating the cover frame around 180°).
Содержание PKA1UMEN-001
Страница 43: ......