EN
23
Installation
www.bora.com
X
X
Turn the angled ducting piece [1].
X
X
Push the rotated angled ducting piece [1] back onto
the ducting piece adapter [2] until the fastening lugs
click into place.
Fig. 6.29 Airflow to the left with angled ducting piece
X
X
Make sure that no air gap has formed between the
components.
X
X
Secure the holding plate.
Rotate the cover frame about 180°.
INFO
In order to correct the direction of the cover
frame, it may need to be rotated around 180°.
Fig. 6.30 Dismounting the cover frame
X
X
Rotate the cooktop extractor and place it down
carefully with the visible surface on a soft surface
(e.g. a blanket).
X
X
Carefully undo the holding clamps (18x) with a
screwdriver.
2
1
Fig. 6.27 Mounting the straight ducting piece
[1]
Straight ducting piece
[2]
Ducting piece adapter
X
X
Push the straight ducting piece [1] onto the ducting
piece adapter [2] until the fastening lugs click into
place.
X
X
Make sure that no air gap has formed between the
components.
X
X
Secure the holding plate to the ducting piece adapter
[2] with just 2 screws.
6.7.2 Airflow to left
(installation rotated around 180°)
INFO
The PKA cooktop extractor can be fitted
rotated around 180° so that the airflow is to
the left.
Airflow to the left with angled ducting piece
X
X
Dismount the holding plate and the angled ducting
piece (see Airflow straight to the side).
X
X
Rotate the cover frame around 180°
(see Rotating the cover frame around 180°).
2
1
Fig. 6.28 Turn angled ducting piece
[1]
Angled ducting piece
[2]
Ducting piece adapter
Содержание PKA1UMEN-001