Attention:
The working-voltage of high-tension cable can be higher than 100,000V.There can be
strong static electricity even when the power was cut-off in short time. Please do not
touch the cable directly.
Installation picture of RECI laser tube
Attention:
Before working, please adjust the focal length. Put the focal length in the middle of
working material and laser outlet before working. C
onvex surface should be faced to working
material when installing focus lens.
High-tension cable
High-voltage insulation protective jacket
Water-in
Water flow direction
Red dot position
Air
compressor
control valve
Focus Lens
3
rd
Reflection
Mirror
Focal length adjusting