User Manual for BCL-X Series Laser Machine
54
cold area should guarantee water should not be freeze, especially when machine stops
working, cooling water must not stay inside in laser tube in case there is any frozen
cooling water to cause explosion.(Special attention: For users who use AC, cooling water
must be connected with ground)
8.2
The two supporting points should be on the 1/4 part of laser tube, and water-flow
should be at the level of 2L-4L per minute. Otherwise the effect is not good, which could
lead to mode hopping. Small change of facula will result in the decrease of power.
Cooling water's water-outlet tube must be submerged in water, or there will occur laser
tube is not filled totally with water when the machine is powered off and on.
8.3
Pay attention to protect laser tube's exit side, to avoid smog sputtering on the exit
surface and pollute it during the process of machine working or laser path adjusting. Or
power will be lower down. The outside of laser tube’s exit side can be cleaned by
absorbent cotton or cloth dipped with alcohol.
8.4
During the debugging, the best output effect can be reached through adjusting laser
tube's supporting position or rotating laser tube's direction, then fix the laser tube.
8.5
Careful attention: avoid dust acceleration on high voltage electrode and keep dry. Be
away from metals as much as possible in case any fire hazard.
8.6
During using laser tube, there should be no scale inside laser tube in case to cause
water plugging and affect cooling effect. Once there is any scale, use 20% diluted
hydrochloric acid to clean cooling tube to eliminate scale.
8.7
Laser tube belongs to glass products, fragile. Avoid local stress when arranging laser
tube.
8.8
Use laser tube properly and save laser power. Laser tube's best power is 80% of rated
power.
IX Common Breakdown Maintenance
Symptoms
Problem analysis
Processing method
No laser
beam during
working
1.Firstly, check if laser tube itself works normally(the
exit of laser),if it works normally
Test if mirrors are damaged and
light path is skewing.
2.The exit of laser tube has no laser, then check if
water recycling works normally(see if water flow is
smooth), if there is no water flow or it's not smooth
clean water pump, dredge water
tube