User Manual for BCL-X Series Laser Machine
24
Optical system of bed is in the inside of gantry. The adjusting of second reflection mirror
is easier. Just adjust the first reflection mirror.
No.1 Screw
Testing method when laser is reflected from first
reflection mirror to second reflection mirror:
Move the second reflection mirror on Y axis at the nearest
and farthest position from first reflection mirror.
From the first reflector to second reflector, the laser beam
should be fell on the same point from both nearest and
farthest position to the first reflector.
Upper--please adjust No.1 screw;
Lower--please adjust No.2 and No.3 screw;
Left—please adjust No.2 screw;
Right—please adjust No.1 and No.3 screw.
No.2 Screw
No.3 Screw
If light on the same point is not on the right side
of the center, please adjust No.11,12,13 screw to
relevant position ( generally don’t need to
require adjustment).
No.11 Screws ( two screws)
No.12 Screws ( two screws)
No.13 Screws ( two screws)