7.5
Start / Stop
There are four possibilities to start the spindle:
✓
manually
with the Start/Stop buttons on the operating panel and the rotary knob for adjusting the
rotational speed (see 7.6)
✓
digitally
with a digital control signal at digital input1
Start/Stop
at SL2.1.
The switching levels for "OFF=0" are 0...7V and for "ON=1" 18...24V,
voltages between 7V and 18V are undefined.
➔
As soon as this is initiated, the spindle will be accelerated to the set value of the
rotational speed which is pre-selected as voltage at analogue input1
Set Value of
Rotational Speed
at SL2.2.
✓
analogue
with a voltage at analogue input1
Precondition is a valid "ON" signal at digital input1
Start/Stop
➔
An input voltage of 0V makes the spindle stop, and a voltage higher than 0,29V
starts the spindle up to a rotational speed according to the scaling.
✓
serial
with start-stop commands via serial interface.
Start and Stop
In the simplest case, a connected and appropriately set up spindle can be started by pressing the Start-
Button. The desired speed can be adjusted by dialing with the rotary knob either as preset value
during standstill or in Run mode. The preconditions for a correct Start can be looked up under 7 and
7.1 .
Any error or malfunction is displayed as plain text
All relevant system messages on rotational speed, load or problems are displayed on the LCD display
The current power output is displayed in the lower part as analogue load bar as % and absolute.
An overload condition will be displayed as well.
The pre selected and current speed, the selected characteristic are displayed
ATTENTION:
The operation of a spindle with an incorrect spindle characteristic may harm the spindle
severely!
Please ensure that the correct characteristic is selected
If several spindles are operated simultaneously, it has to be ensured that they are of the
same type and that a specific characteristic is selected.
Otherwise this may harm one or more spindles or the converter severely!
Содержание SFU 0303
Страница 1: ... wenn es um Qualität geht BMR GmbH 1 ...
Страница 7: ... wenn es um Qualität geht BMR GmbH 7 3 Block Diagram ...
Страница 55: ... wenn es um Qualität geht BMR GmbH 55 17 Mechanic Views and Dimension 17 1 SSE Version for cabinet mounting ...
Страница 56: ...56 SFU 0303 Frequenzumrichter 17 2 19 Version ...
Страница 57: ... wenn es um Qualität geht BMR GmbH 57 17 3 Version Desktop ...
Страница 58: ...58 SFU 0303 Frequenzumrichter ...
Страница 61: ... wenn es um Qualität geht BMR GmbH 61 ...
Страница 62: ...62 SFU 0303 Frequenzumrichter ...