12
SFU 0303
Frequenzumrichter
6.1
Digital and Analog Inputs Version SSE: X2
(10 pin pluggable screw terminal
)
The Default-settings of the functions for the outputs can be set up freely with the help of the PC-
Software SFU-Terminal.
✓
Switching level digital inputs: Log"0" = 0…7V /
Log"1" = 18….24V SPS Standard level
✓
Analogue input range: 0…10V
✓
The +24V at Pin 10 can be used as auxiliary voltage supply for Start / Stop signal with the help of a
relay or for an electronic spindle interface.
Pin Description Description Function / default Setting
Switching state
1 Digital In 1
Input
Start / Stop
"0" Stop / "1" Start
2 Digital In 2
Input
Power Stage Pulse Lock Inhibitor /
no function with Version STO
"0" activated / "1" released
3 Digital In 3
Input
Power Stage Off
"0" Aus / "1" On
4 Digital In 4
Input
Locked / Emergency Stop
"0" released / "1" Emergency Stop
5 Digital In 5
Input
Error reset
"0" Errors have to be reset,
with Hi level on this Input or
with any Start signal
"1" Errors are rest automatically
6 Digital In 6
Input
Direction of rotation
"0" unchanged / "1" inverted
7 Analog In 1
Input
Set value Rotational speed
Scaling 10V min/max
rot. speed converter
1V/10.000
8 Analog In 2
Input
Set value Varioload
active load
1V/10.000
9 GND
Reference Ground for die Digital and
Analog signals
10 + 24V/50ma
Output
Auxiliary voltage supply
Содержание SFU 0303
Страница 1: ... wenn es um Qualität geht BMR GmbH 1 ...
Страница 7: ... wenn es um Qualität geht BMR GmbH 7 3 Block Diagram ...
Страница 55: ... wenn es um Qualität geht BMR GmbH 55 17 Mechanic Views and Dimension 17 1 SSE Version for cabinet mounting ...
Страница 56: ...56 SFU 0303 Frequenzumrichter 17 2 19 Version ...
Страница 57: ... wenn es um Qualität geht BMR GmbH 57 17 3 Version Desktop ...
Страница 58: ...58 SFU 0303 Frequenzumrichter ...
Страница 61: ... wenn es um Qualität geht BMR GmbH 61 ...
Страница 62: ...62 SFU 0303 Frequenzumrichter ...