21
6.9
Mains and Spindle Connection - Desktop Version:
The connection with mains network is carried out with an IEC connector
The device is equipped with a Thermo-Automatic Fuse for each prong. They can be reset after tripping
by pressing down the button
The spindle connection is realized on custom order and can be realized accordingly
Backside SFU0303-Desktop equipped with a 7pin circular spindle connection
Several Circular Connectors can be mounted:
Spindle Connection
7pin female Binder Series 693 or Amphenol C16-1
IEC Eurobuchse
Sicherungsautomaten
Sicherungsautomaten
I/O Interface
Spindel Interface
Spindelanschluss
Control wires, Mains cables and spindle cables should be installed separately.
For wiring, the use of shielded cables is recommended
Pin
Name
Description
6
SGND
Signal GND for TempSensor- and FP-Signal
5
W
Spindle Phase 3
4
FP
speed sensor of the spindle
7
PE
Protective Earth
3
V
Spindle Phase 2
2
Temp-
sensor
Temperature signal from spindle: PTC, KTY, PT1000
1
U
Spindle Phase 1
Содержание SFU 0303
Страница 1: ... wenn es um Qualität geht BMR GmbH 1 ...
Страница 7: ... wenn es um Qualität geht BMR GmbH 7 3 Block Diagram ...
Страница 55: ... wenn es um Qualität geht BMR GmbH 55 17 Mechanic Views and Dimension 17 1 SSE Version for cabinet mounting ...
Страница 56: ...56 SFU 0303 Frequenzumrichter 17 2 19 Version ...
Страница 57: ... wenn es um Qualität geht BMR GmbH 57 17 3 Version Desktop ...
Страница 58: ...58 SFU 0303 Frequenzumrichter ...
Страница 61: ... wenn es um Qualität geht BMR GmbH 61 ...
Страница 62: ...62 SFU 0303 Frequenzumrichter ...