2) With SFU-Terminal the "active" function of the relays can be changed to "not energized " also. By
this an inversion is achieved, with the restriction that this is applied to the inverter during operation at
POWER-ON, only, because it is just realized by software. At POWER-OFF, the relay contacts have the
default setting as in 1 )
✓
The digital outputs (Relay1...5) are galvanically separated (500V
Isolation
).
DC: 24V / 1000mA
AC: 125V / 500mA
✓
Output level Speed / Hall Sensor: 0-24V (24V Level)
6.3
Spindle Interface - Version SSE: X4
(9 pin Pluggable screw terminal)
The Default-settings of the functions for the inputs can be set up freely with the help of the PC-
Software SFU-Terminal. The inputs of the encoder and the PTC are fix wired.
Pin
Description
Direction
Function
1
+12V/50mA
Output
Auxiliary voltage supply
2
Spindle GND
Reference Ground for Speed- and Temp-sensor
3
NC
not connected
4
FP/Speed sensor
Input
Input for 2/3-wire speed sensors /
Hall sensors from spindle
5
Temperature
Sensor
Input
Temperature signal from spindle: PTC, KTY, PT1000
6
Bit 4
Input
Characteristic selection by digital inputs
7
Bit 3
Input
Characteristic selection by digital inputs
8
Bit 2
Input
Characteristic selection by digital inputs
9
Bit 1
Input
Characteristic selection by digital inputs
Содержание SFU 0303
Страница 1: ... wenn es um Qualität geht BMR GmbH 1 ...
Страница 7: ... wenn es um Qualität geht BMR GmbH 7 3 Block Diagram ...
Страница 55: ... wenn es um Qualität geht BMR GmbH 55 17 Mechanic Views and Dimension 17 1 SSE Version for cabinet mounting ...
Страница 56: ...56 SFU 0303 Frequenzumrichter 17 2 19 Version ...
Страница 57: ... wenn es um Qualität geht BMR GmbH 57 17 3 Version Desktop ...
Страница 58: ...58 SFU 0303 Frequenzumrichter ...
Страница 61: ... wenn es um Qualität geht BMR GmbH 61 ...
Страница 62: ...62 SFU 0303 Frequenzumrichter ...