…wenn es um Qualität
geht!
BMR GmbH
9
4.2
Version 19" und Desktop
ATTENTION
The operation of a spindle with a wrong characteristic may harm the spindle or
converter severely! Please ensure to have the proper characteristic selected always!
Mains connection
115V, 60Hz
230V, 50Hz
3-pin: plugable screw terminals 4mm²
Continuous output power
2 kVA / S1-100%
3,6 kVA / S1-100%
Motor connection
Output voltage
110V
220V
Output current
Output current overload
Output frequency
Spindle characteristics
Spindle sensor inputs
Control inputs
2 Analog: 0-10V
6 Digital: 0-24V
2 STO: 0-24V
Control outputs
Interface
Dimensions
Weight
Protection
Operating conditions
5 - 40°C / rel. humidity max. 85%
IP20
- USB on operating panel (USB-Mini)
- RS232, RS485 on SFU (9 pol DSub male)
- Profibus on Option as module, replacing operating panel
9-pin: plugable screw terminals 4mm²
U, V, W, Temperature sensor, FP, SGND, 2x PE or
Circular connector 7 or 13 Pin
U,V,W,FP,SGND,Shield, PE
elektronically limited, max. 13A
2 Analog: 0-10V
5 x Digital, freely to be setup
1 x Digital reserved for power stage impuls inhibitor or STO
Relay contacts, 24VDC/1000mA, 125VAC/500mA
12 pin plugable screw terminals X3
see chap 17
approx. 6 kg depending on version
Speed sensor, PTC, KTY, PT1000
maximum duration adjustable 0…20sec
AC: max 8,8kHz / 500.000 rpm
DC: max 1.667Hz / 100.000 rpm
max. 16, stored internally
Содержание SFU 0303
Страница 1: ... wenn es um Qualität geht BMR GmbH 1 ...
Страница 7: ... wenn es um Qualität geht BMR GmbH 7 3 Block Diagram ...
Страница 55: ... wenn es um Qualität geht BMR GmbH 55 17 Mechanic Views and Dimension 17 1 SSE Version for cabinet mounting ...
Страница 56: ...56 SFU 0303 Frequenzumrichter 17 2 19 Version ...
Страница 57: ... wenn es um Qualität geht BMR GmbH 57 17 3 Version Desktop ...
Страница 58: ...58 SFU 0303 Frequenzumrichter ...
Страница 61: ... wenn es um Qualität geht BMR GmbH 61 ...
Страница 62: ...62 SFU 0303 Frequenzumrichter ...