13
6.2
Digital and Analog Outputs Version SSE: X3
(12 pin Pluggable screw terminal )
The Reference-Ground for digital and analog signals: Clamp terminal X2.9
The Default-settings of the functions for the outputs can be set up freely with the help of the PC-
Software SFU-Terminal.
An exception is the signal "Power Stage Pulse Lock", which is linked fix with Relay 6.
According to
the switch state it will be output 0V / GND or +24V via 10k
Ω
referring to GND
(X2.9) (-> 8.2 / 8.7)
+24V: Output Power Stage released 0V: Output Power Stage locked.
✓
Relay Output:
1) default = "not energized" corresponds to "not active"
inactive condition at opener (NC contact)
→
Contact closed
inactive condition at closer (NO contact)
→
Contact opened
Pin
Description
Direction
Function / Message / default Setting
1
Relay Common
Common Rail Relay 1…5
2
Relay 6 normally closed
Output
Feedback signal for
Power Stage Pulse
Lock
state
3
Relay 5 normally closed
Output
Excess temperature
Converter of Spindle
4
Relay 4 normally closed
Output
Overload
5
Relay 3 normally closed
Output
Standstill
Converter and Spindle
6
Relay 2 normally closed
Output
Spindle Ready
7
Relay 2 normally open
Output
8
Relay 1 normally closed
Output
Converter Ready
9
Relay 1 normally open
Output
10
Analog Out 1
Output
11
Analog Out 2
Output
12
Hall Sensor-Output
Output
modified signal square shape signal from encoder
Содержание SFU 0303
Страница 1: ... wenn es um Qualität geht BMR GmbH 1 ...
Страница 7: ... wenn es um Qualität geht BMR GmbH 7 3 Block Diagram ...
Страница 55: ... wenn es um Qualität geht BMR GmbH 55 17 Mechanic Views and Dimension 17 1 SSE Version for cabinet mounting ...
Страница 56: ...56 SFU 0303 Frequenzumrichter 17 2 19 Version ...
Страница 57: ... wenn es um Qualität geht BMR GmbH 57 17 3 Version Desktop ...
Страница 58: ...58 SFU 0303 Frequenzumrichter ...
Страница 61: ... wenn es um Qualität geht BMR GmbH 61 ...
Страница 62: ...62 SFU 0303 Frequenzumrichter ...