Connections, Interfaces and Pinouts
For embedding into PLC and controls the SFU0303 has several input and outputs.
They are realized as pluggable screw terminals and are located at the front or rear panel (depending
on case option). All contacts are separated galvanically from high voltage carrying circuits.
Operational parameters and outputs:
The
SFU-0303
captures all current important operational parameters and operating data.
Up to 6 digital outputs can be used for signaling and up to 2 analogue values can be output to the
analogue outputs (0-10V).
Remote Control and Outputs:
6 digital inputs (24V) and 2 analogue inputs (0-10V) are available for remote control of the
SFU-0303
.
These assignments can be configured freely. By using the optional Windows PC software "
SFU-
Terminal"
the above mentioned assignments can be achieved easily, providing exceptional flexibility
with each application.
Each operating parameter can be assigned as a signal and each control signal can be assigned to a
certain I/O pin. In addition, the logic level (high or low active) can be individually defined.
The same assignment is also possible for the analogue measured data and control data at the analogue
I/O pin.
The standard allocations of operational parameters, their outputs, control signals and inputs, are listed
in the following tables.
ATTENTION
Please verify that all power supply voltages are correct in polarity and value.
ATTENTION
Please ensure to have the proper characteristic selected, always!
The operation of a spindle with a wrong characteristic may harm the spindle severely!
ATTENTION
In case of replacing the fuses, please ensure to use types only, which are
mentioned in 'Technical Data'!
Содержание SFU 0303
Страница 1: ... wenn es um Qualität geht BMR GmbH 1 ...
Страница 7: ... wenn es um Qualität geht BMR GmbH 7 3 Block Diagram ...
Страница 55: ... wenn es um Qualität geht BMR GmbH 55 17 Mechanic Views and Dimension 17 1 SSE Version for cabinet mounting ...
Страница 56: ...56 SFU 0303 Frequenzumrichter 17 2 19 Version ...
Страница 57: ... wenn es um Qualität geht BMR GmbH 57 17 3 Version Desktop ...
Страница 58: ...58 SFU 0303 Frequenzumrichter ...
Страница 61: ... wenn es um Qualität geht BMR GmbH 61 ...
Страница 62: ...62 SFU 0303 Frequenzumrichter ...