7.4.3
Error Messages:
The following error displays are possible:
Display
Error
Pulse Blocking!!
Power stage lock active / converter locked
STO Pulse Blocking
Power stage lock STO active / converter locked
STO Error
Uneven signal on STO inputs / converter locked
Overload Stopp
Spindle Overload. The admissable maximum power is superceeded
Overtemp. SFU
Overtemp converter
Overtemp. Spin
Excess temperatur in spindle or temp input not properly wired
Overvoltage trip!
Mains voltage too high
Undervoltage trip
Mains voltage too low
Undervoltage stop
Mains voltage too low
Pwr stage off!
Power stage switched off and disabled
Emgcy stp active !
Emergency input engaged / converter locked
No Spindle !
Without spindle or cable defective
RS232 Error !
Timeout serial interface
Diagram Error !
Invalid characteristic
Encoder Error !
Error with speed sensor / hall sensor
Back engy trip
Error Power Stage switch off because of deceleration ramp too high
Err. B.Eng/Stall
Error with BLDC spindle: Spindle is blocked or has lost commutation
GND fault !
Error: PE is connected with one or more spindle lines or convert is defective
Содержание SFU 0303
Страница 1: ... wenn es um Qualität geht BMR GmbH 1 ...
Страница 7: ... wenn es um Qualität geht BMR GmbH 7 3 Block Diagram ...
Страница 55: ... wenn es um Qualität geht BMR GmbH 55 17 Mechanic Views and Dimension 17 1 SSE Version for cabinet mounting ...
Страница 56: ...56 SFU 0303 Frequenzumrichter 17 2 19 Version ...
Страница 57: ... wenn es um Qualität geht BMR GmbH 57 17 3 Version Desktop ...
Страница 58: ...58 SFU 0303 Frequenzumrichter ...
Страница 61: ... wenn es um Qualität geht BMR GmbH 61 ...
Страница 62: ...62 SFU 0303 Frequenzumrichter ...