Appendix B: Gas Type Conversion
87
Blue Seal Evolution Series Gas Convection Ranges
© Copyright Moffat Ltd. 21 June 2016
Amendment 13
- United Kingdom
Appliance Classification
Category:
II
2H3P.
Flue Type:
A
2.
*
Measure burner operating pressure at manifold test point with two burners operating at the ‘High’ setting.
Operating pressure is ex-factory set through the appliance regulator and is not to be adjusted, apart from when
carrying out gas conversion, if required. (Refer to the ‘Gas Conversion’ section for details).
Natural Gas
(G20)
Propane
(G31)
Open Burner
Main Burner Injectors
Ø 2.30mm
Ø 1.40mm
Pilot Burner ('PF' Models Only)
0.30
0.20
Griddle
Main Burner
Ø 2.10mm
Ø 1.30mm
Pilot Burner
0.35
0.23
Burner Aeration Setting
Fully Open
Fully Open
Oven
Main Burner
Ø 2.60mm
Ø 1.60mm
Pilot Burner
0.35
0.23
Burner Aeration Setting
Fully Open
Fully Open
Supply Pressure
20 mbar
37 mbar
Operating Pressure (*)
9.5 mbar
26 mbar
Gas Regulator Cap Screw