Fault Finding
15
Blue Seal Evolution Series Gas Convection Ranges
© Copyright Moffat Ltd. 21 June 2016
Amendment 13
Fault
Possible Cause
Remedy
Pilot flame small / lazy / yellow.
(PF fitted burners only).
Gas pressure too low.
Blocked / incorrect size pilot
injector.
Check gas supply pressure.
(Refer Specifications Section).
Clean or replace pilot injector.
(Refer Service section 6.2.3 / 6.3.6).
Pilot goes out when knob released.
(PF fitted burners only).
Releasing knob before the thermocouple is
heated.
Pilot flame too small.
(Refer fault: Pilot Flame Small).
Thermocouple faulty.
(Refer Fault Diagnosis 5.2.1).
Gas control magnet faulty.
(Refer Fault Diagnosis 5.2.1).
Hold control knob in for longer (10 sec),
see if pilot will stay lit.
Correct fault.
Replace thermocouple.
(Refer Service Section 6.2.4 / 6.3.4).
Replace gas control magnet.
(Refer Service Section 6.3.7).