B
Appendix B: Gas Type Conversion
86
Blue Seal Evolution Series Gas Convection Ranges
© Copyright Moffat Ltd. 21 June 2016
Amendment 13
Gas Specifications
- Australia
- New Zealand
*
Measure burner operating pressure at manifold test point with two burners operating at the ‘High’ setting.
Operating pressure is ex-factory set through the appliance regulator and is not to be adjusted, apart from when
carrying out gas conversion, if required. (Refer to the ‘Gas Conversion’ section for details).
Natural Gas
LP Gas (Propane)
Open
Burner
Main Burner
Ø 2.45mm
Ø 1.50mm
Pilot Burner ('PF' Models Only)
0.30
0.20
Griddle
Main Burner
Ø 2.10mm
Ø 1.30mm
Pilot Burner
0.35
0.23
Burner Aeration Setting
Fully open
Fully open
Main Burner
Ø 2.60mm
Ø 1.60mm
Pilot Burner
0.35
0.23
Burner Aeration Setting
Fully Open
Fully Open
Supply Pressure
1.13 - 3.40kPa
2.75 - 4.50kPa
Burner Operating Pressure (*)
0.95kPa (*)
2.6kPa (*)
Gas Regulator Cap Screw
Oven
Natural Gas
LP Gas
Open
Burner
Main Burner
Ø 2.45mm
Ø 1.50mm
Pilot Burner ('PF' Models Only)
0.30
0.20
Griddle
Main Burner
Ø 2.10mm
Ø 1.30mm
Pilot Burner
0.35
0.23
Burner Aeration Setting
Fully open
Fully open
Main Burner
Ø 2.60mm
Ø 1.60mm
Pilot Burner
0.35
0.23
Burner Aeration Setting
Fully Open
Fully Open
Supply Pressure
1.13 - 3.40kPa
2.75 - 4.50kPa
Burner Operating Pressure (*)
0.95kPa (*)
2.6kPa (*)
Gas Regulator Cap Screw
Oven