B
Appendix B: Gas Type Conversion
84
Blue Seal Evolution Series Gas Convection Ranges
© Copyright Moffat Ltd. 21 June 2016
Amendment 13
Main Burner Injector
Pilot Burner
Piezo Igniter
Thermocouple
Main Burner
Aeration Slide
Burner Adjustment Screw
Convection Oven
1.
Carry out the following:-
Remove lower lintel at front of oven.
Open oven door and remove sole plate(s).
Loosen clamp bracket and remove main burner.
Remove thermocouple and piezo igniter from mount-
ing bracket. (For access purposes).
Disconnect pilot supply tube from pilot burner to ac-
cess pilot injector.
2.
With Main Burner removed, ensure aeration gap is adjusted for type of gas being used as
shown in ‘Gas Specifications Tables’ at end of this section.
3.
Remove pilot and main injectors and replace with correct size injectors as shown in ‘Gas
Specifications Tables’ at end of this section.
4. Refit
the
following:-
Re-connect pilot supply tube to pilot burner.
Re-connect piezo igniter and thermocouple to mounting bracket.
Refit main burner and secure clamp bracket.
Refit sole plate(s) and lower lintel.
NOTE:
There is no 'Low Fire' adjustment on the gas control valve for the GC Oven.
Refit the oven control panel.