IM0001_L2_R_WMv1.3
7
Charger assembly layout
The charger assembly should be mounted on the wall in close proximity to the vehicle stall and at a
location where the 18-foot charging cord can be easily connected to the vehicle charging port
without the cord stretching taut and/or presenting a trip hazard.
The charger assembly must be mounted at a height (minimum 18 inches [460 mm] above floor)
where the panel display can be easily seen and monitored by the operator. A height of 60 inches
(152 cm) to the center of the display is suggested. The cord reel can be mounted below or in another
location near the charger assembly that best accommodates the user’s preferences and comfort. The
charger assembly and cord reel may be installed on adjacent walls (corner mounted). For cord-
connected
blinks
(Models WE-30K and WE-48K), there must be sufficient space allowed between
the charger assembly and mounting of the cord reel for installation of the 6-50R receptacle. .
WARNING: RISK OF FIRE
This equipment has arcing or sparking parts that must not be exposed to flammable vapors.
This equipment must be located at least 18 inches (460 mm) above the floor.
Figure 1 – blink Installations, Typical
Содержание Wall Mount Charging System
Страница 1: ...Wall Mount Charging System Installation Manual Simply Smart ...