11.4.11 U.ANALO Submenu
This submenu contains the configuration parameters of the analogue output.
TYPE
VOLT, I0_20, I4_20
This selects output in voltage (0-10 V) or in
current (0/20 mA or 4/20mA)
DATA
GROSS, NET, REFWEI
selects outgoing data
VMIN
Output calibration at 0 Volt
VMAX
Output calibration at 10 Volt
IMIN
Output calibration at 0 mA
IMAX
Output calibration at 20 mA
11.4.12 Fn KEY Submenu
This submenu contains the configuration of the secondary function of the
numeric keys.
of the numeric keys.
You can enable the quick retrieval of retrievable data with
.
To associate a data/function to a quick retrieval, do the following:
1) Select the data/function that you wish to associate to a quick key by
repeatedly pressing
.
2) Press
and hold it down until “Prog.fn” and “Sel.kn” appear in
sequence
3) Press the number key where you wish to save the data.
4) To retrieve the saved data press
, this function is reported by
the “Fn” LED lighting up, followed by the previously selected number
key (F1/F10).