![Bilanciai D70ES Скачать руководство пользователя страница 104](http://html1.mh-extra.com/html/bilanciai/d70es/d70es_use-and-maintenance-manual_2750937104.webp)
D70ES
1-104
menu.
RANGE
Output1 is activated in the weight interval
defined by the range. The 'MIN1' and 'MAX1'
messages appear in the terminal's main menu,
i.e. the maximum and minimum weights of the
weight range, respectively.
ESTRAZ
Output1 is activated by the star t signal. When
the defined weight is exceeded or the STOP
input is activated, the output is deactivated.
The terminal’s main menu display ‘ESTRAZ’,
‘SLOW’(optional) and ‘FALL’.
If there is no need to define ‘FALL’ It must to be
set to ‘0’.
STMP.OK
This activates the output for 1 second if
transmission or printout has taken place
correctly.
OUT02
This selects 02 output operation
DISAB
Output disabled
SETPNT
Output2 is activated when the weight defined
by
Setpoint 2 has exceeded.
'SETPN2' will appear in the terminal's main
menu.
RANGE
Output2 is activated in the weight interval
defined by the range. The 'MIN2' and 'MAX2'
messages appear in the terminal's main menu,
i.e. the minimum and maximum weights of the
weight range, respectively.
SLOW
This needs to be activated in combination with
EXTRAC on output1. This manages extraction
systems that need two dosing speeds.
Output2 is deactivated when the 'EXTRC'-
'SLOW' weight is reached or when the STOP
command is activated.
'SLOW' will appear in the terminal's main