Characters such as <s1>, <s2>, <s3>, <s4> are ASCII characters that must
be interpreted as hexadecimals. Each character represents 4 bits with
different meanings, for example incoming ASCII character "A" must be
interpreted as hexadecimal digit "A";
1
0
1
0
bit3
bit2
bit1
bit
When a bit has a value of "1" this means that the corresponding signal is in
the true condition; the meaning of the signals is as follows:
<s1>
bit 0
minimum weighing operation signal
bit 1
blocked tare signal
bit 2
preset(1)/self-weighing(0) tare
signal
bit 3
"center zero" signal
<s2>
bit 0
not used
bit 1
stable weight signal
bit 2
overload signal
bit 3
not used
<s3>
bit 0
entered tare signal
bit 1
not used
bit 2
invalid weight
bit 3
printing in progress
<s4>
bit 0
approved instrument
bit 1
failed converter
bit 2
error on scale configuration parameters
bit 3
Indication that weight is too negative
Available protocols: Cyclic (see
par. 9.3.2 on page 1-68
), ACK-NAK (see
par.
9.3.1 on page 1-68
), Remote commands (see
par. 9.4 on page 1-69).
The pause between the end of one string and the beginning of the next is
300 ms ± 10%.