![Bilanciai D70ES Скачать руководство пользователя страница 85](http://html1.mh-extra.com/html/bilanciai/d70es/d70es_use-and-maintenance-manual_2750937085.webp)
1-85
D70ES
checksum characters are "6"
(36H) and "2" (32H).
33rd
– 36
th character
<CRC>
CRC16(optional)
MPP String
STD–DA + ABTA=YES
the transmitted data is:
1st character
$(24H)
2nd character
M(4DH)
3rd character
P(50H)
4th -13
th
Date (dd/mm/yyyy)
Date (10 characters)
14
th
Space(20H)
15
th-22nd
Hour(hh:mm:ss)
Hour (10 characters)
23rd
Space(20H)
24th-30th character
MPP identification
code or indications on
scale status:
NO<SP>STAB weight not stable
NO<SP>VAL<SP> invalid weight
ERRMEM<SP> weight
storage error
31st
N(4EH)
32nd
Space(20H)
33rd-40th character
Net Weight with mark and any
decimal separator
41st-42nd character
<um>
Unit of measurement
43rd
T(54H)
44
th
Space(20H)
45th- 52nd
Tare Weight with mark and any
decimal separator
53rd -54th
<um>
Unit of measurement
55th-56th character
<CRC>
String command field; it is
calculated by running an XOR (or
exclusive) operation of all
previous characters. The
calculated value is expressed
with two hexadecimal characters,
e.g.
if the result is 62H the two
checksum characters are "6"
(36H) and "2" (32H).
57 th-60th character
<CRC>
CRC16 (optional)