Address Name
Range
Units
R/W
Description
(for full description see Section 6)
166
DI1 Function
0 - 7
-
RW
0 = OFF, 1 = SLOW EN, 2 = S.A.C., 3 = CLR.M.,
4 = VC EN, 5 = ACQ EN, 6 = I.C.SVC, 7 = I.C.RL
167
Reserved
0 - 7
-
R
-
168
DI1 Active If
0 - 1
-
RW
0 = Absent, 1 = Present
169
Reserved
0 - 1
-
R
-
170
DI1 Status
0 - 1
-
R
0 = Low, 1 = High
171
DI2 Function
0 - 7
-
RW
0 = OFF, 1 = SLOW EN, 2 = S.A.C., 3 = CLR.M.,
4 = VC EN, 5 = ACQ EN, 6 = I.C.SVC, 7 = I.C.RL
172
Reserved
0 - 7
-
R
-
173
DI2 Active If
0 - 1
-
RW
0 = Absent, 1 = Present
174
Reserved
0 - 1
-
R
-
175
DI2 Status
0 - 1
-
R
0 = Low, 1 = High
176
DI3 Function
0 - 7
-
RW
0 = OFF, 1 = SLOW EN, 2 = S.A.C., 3 = CLR.M.,
4 = VC EN, 5 = ACQ EN, 6 = I.C.SVC, 7 = I.C.RL
177
Reserved
0 - 7
-
R
-
178
DI3 Active If
0 - 1
-
RW
0 = Absent, 1 = Present
179
Reserved
0 - 1
-
R
-
180
DI3 Status
0 - 1
-
R
0 = Low, 1 = High
181
Reserved
0 - 7
-
R
-
182
Reserved
0 - 7
-
R
-
183
Reserved
0 - 1
-
R
-
184
Reserved
0 - 1
-
R
-
185
Reserved
0 - 1
-
R
-
186
Reserved
0 - 7
-
R
-
187
Reserved
0 - 7
-
R
-
188
Reserved
0 - 1
-
R
-
189
Reserved
0 - 1
-
R
-
190
Reserved
0 - 1
-
R
-
191
Analog Output
Enabled
0 - 1
-
RW
0 = No, 1 = Yes
192
Analog Output
Selected
0 - 1
-
RW
0 = Position, 1 = Pressure
193
Analog Output
Supply
0 - 1
-
RW
0 = Internal, 1 = External
194
Analog Output
Operating Mode
0 - 1
-
RW
0 = Normal, 1 = Reverse
195
Analog Output
Value
0 - 2000
mA
R
0 = 0,00
196
Reserved
0 - 4095
-
R
-
197
Reserved
0 - 4095
-
R
-
198
Bluetooth Enabled
0 - 1
-
RW
0 = No, 1 = Yes
199
Bluetooth Type
0 - 1
-
R
0 = Short, 1 = Long
200
Bluetooth Name
-
R
Bluetooth Name (MSB)
201
Bluetooth Name
-
R
-
202
Bluetooth Name
-
R
-
203
Bluetooth Name
-
R
-
204
Bluetooth Name
-
R
-
205
Bluetooth Name
-
R
Bluetooth Name (LSB)
206
RS232 Enabled
0 - 1
-
RW
0 = No, 1 = Yes
207
RS485 Enabled
0 - 1
-
RW
0 = No, 1 = Yes
208
RS485 Termination
Active
0 - 1
-
RW
0 = No, 1 = Yes
209
Modbus Enabled
0 - 1
-
R
0 = No, 1 = Yes
210
Modbus Address
1-247
-
R
-