
Service and Maintenance for Mortise Locks
W Series Service Manual
4–45
5. Position the bracket so that the RQE actuator button is on the same
end as the pivot point of the switch hub lever. Gently bend the
bracket feet apart and slide the bracket forward on the switch until
the bracket tabs enter the two switch mounting holes.
6. Clamp the wires in the strain relief. Slide the strain relief into
position on the case. It should lock into place.
7. Tilt the RQE switch forward and slide it into place in the case.
Task D. To reinstall the hubs:
1. Push the hub lever toward the side of the case and slide the now
bottom hub under the auxiliary levers.
2. Insert the now top hub onto the bottom hub.
Figure 4.42
Assembled RQE switch assembly
Switch bracket feet
Switch mounting holes
Bracket tabs
Figure 4.43
Turning over the hubs and cylinder clamp plate
(IDH Max, LHRB orientation shown)
Top hub
Cylinder clamp plate
Hub lever
Auxiliary levers
Содержание 34HW
Страница 1: ......
Страница 6: ...Contents vi W Series Service Manual...
Страница 38: ...IDH Max Locks Functions and Parts 2 24 W Series Service Manual...
Страница 54: ...Electrified Locks Functions and Parts 3 16 W Series Service Manual...
Страница 140: ...Service and Maintenance for Cylindrical Locks 5 30 W Series Service Manual...
Страница 158: ...Additional Service and Maintenance for IDH Max Locks 6 18 W Series Service Manual...
Страница 162: ...Glossary A 4 W Series Service Manual...
Страница 164: ...Installation Instructions B 2 W Series Service Manual...