Installation Instructions for 34HW–35HW IDH Max Mortise Locks
BEST ACCESS SYSTEMS
Indianapolis, Indiana
Completing the installation at the door
16
18
Install wire transfer hinge
1 Trim the four wires of the field wire harness, which you
pulled through the hinge edge of the door in Task 8.
Leave sufficient length to connect to the wire transfer
hinge.
2 Splice the power and communication field wiring to
the four pairs of leads on the frame side of the hinge,
following the hinge manufacturer’s instructions.
3 Splice the four field wire harness wires (listed in the
table below) to the four pairs of leads on the door side
of the hinge, matching each pair of leads to its
corresponding field wire.
4 Insert the wires and splice connectors into the holes or
pockets in the door and frame, being careful not to
pinch the wires. Install the wire transfer hinge.
Wire
Color
Ground
Black
12 VDC
Red
Com+
Orange
Com–
Green
Figure 18 Installing the wire transfer hinge
Access holes
Field wire
harness leads
Wire transfer
hinge
Door frame
Field wires
Splice
connectors
Door
Содержание 34HW
Страница 1: ......
Страница 6: ...Contents vi W Series Service Manual...
Страница 38: ...IDH Max Locks Functions and Parts 2 24 W Series Service Manual...
Страница 54: ...Electrified Locks Functions and Parts 3 16 W Series Service Manual...
Страница 140: ...Service and Maintenance for Cylindrical Locks 5 30 W Series Service Manual...
Страница 158: ...Additional Service and Maintenance for IDH Max Locks 6 18 W Series Service Manual...
Страница 162: ...Glossary A 4 W Series Service Manual...
Страница 164: ...Installation Instructions B 2 W Series Service Manual...