Service and Maintenance for Mortise Locks
4–14
W Series Service Manual
5. Splice the four field wire harness leads (listed in the table below) to
the door side of the hinge, matching each pair of leads to its
corresponding field wire.
6. Insert the wires and splice connectors into the holes or pockets in
the door and frame, being careful not to pinch the wires. Install the
wire transfer hinge.
Task B. To reinstall the mortise case:
1. Insert the mortise case into the mortise cavity, while feeding the
sensor and solenoid wires into the mortise cavity and out the sensor
& solenoid wire hole to the inside of the door.
Note:
The field wire harness should be routed above and behind the
mortise case (depending on where the hole through the door meets
the mortise cavity).
2. Make sure there are 3
″
to 4
″
of slack in the field wire harness to
allow access to the control electronics circuit board in the inside
escutcheon.
Wire
Color
Ground
Black
12 VDC
Red
Com+
Orange
Com–
Green
Figure 4.14
Reinstalling the wire transfer hinge
Access holes
Field wire
harness leads
Wire transfer
hinge
Door frame
Field wires
Splice
connectors
Door
Содержание 34HW
Страница 1: ......
Страница 6: ...Contents vi W Series Service Manual...
Страница 38: ...IDH Max Locks Functions and Parts 2 24 W Series Service Manual...
Страница 54: ...Electrified Locks Functions and Parts 3 16 W Series Service Manual...
Страница 140: ...Service and Maintenance for Cylindrical Locks 5 30 W Series Service Manual...
Страница 158: ...Additional Service and Maintenance for IDH Max Locks 6 18 W Series Service Manual...
Страница 162: ...Glossary A 4 W Series Service Manual...
Страница 164: ...Installation Instructions B 2 W Series Service Manual...