Installation Instructions for 34HW–35HW IDH Max Mortise Locks
BEST ACCESS SYSTEMS
Indianapolis, Indiana
Installing the lock
10
11
Install cylinder and mortise case
faceplate
Note:
Install the cylinder for EEL and EEU function locks
only.
1 Thread the concealed cylinder into the mortise case so
that the groove around the cylinder head is even with
the door surface. Adjust the cylinder depth plus or
minus one (1) turn so that the core, when installed in
the cylinder, is flush with the outer surface of the trim.
Caution:
A malfunction can occur if the cylinder is
threaded in too far.
2 Secure the cylinder in the mortise case with the case
set screw.
3 Secure the mortise case faceplate to the mortise case
with the faceplate mounting screws.
4 Check the cylinder and lock for proper operation.
Figure 11 Installing the cylinder and mortise case faceplate
Outside of door
Concealed
cylinder
Case set screw
(inside mortise case)
Mortise
case
faceplate