77
3.11 Maintenance
It is mandatory to perform maintenance and cleaning of the device at
least once a year.
b
The non-performance of the annual maintenance will invalidate
the warranty.
This operation, carried out by Technical Assistance Centre or by pro-
fessionally qualified personnel, is necessary to monitor and ensure
that the flue pipes inside and outside of the device, the fan, the safety
valves, the condensate removal devices, the water drainage tubes
and all the measurement and control devices are in perfect working
order.
Table of the compulsory maintenance activities (to be per-
formed every 2000 working hours or at least once a year)
Make the combustion test
Check the conditions of the inlet pipes (if present) and the flue
pipes by making sure that no leakage is present
Check the ignition electrode
Clean the combustion chamber and check the conditions of the
gaskets you have dismantled during such operation
Clean the condensate discharge pipe
Check the parameters settings
Check if there is any gas leakage
Check if there is any leakage on the hydraulic connections
Check the integrity of the cabling system and its related connec-
tions
Make sure the ignition takes place regularly
Make sure that there is the flame after ignition
Check the safety devices down the equipment
Check the system pressure
b
Before carrying out any maintenance or cleaning, disconnect
the power from the device by turning off the bipolar main switch
and closing the main gas valve. In addition, for all maintenance
(to be carried out at least once a year, as noted above) always
replace all the flue and gas seals, in particular the burner seals.
Before performing any operation:
- disconnect the electric power supply by turning the main sys-
tem switch to "off"
- close the gas shut-off valve.
3.11.1 "Service reminder" function
The thermal module is fitted with a function that reminds the user of
the need to carry out planned maintenance on the appliance after a
number of hours defined in the maintenance plan.
When this maintenance activity is required, the following text appears
on the normal display:
"Maintenance required!"
This text will remain active until the technical support service resets
the internal meter after maintaining the appliance.
The user can check at any time how many hours miss from the next
planned maintenance activity by accessing the "Information” menu
“
Menu
”
“
Central Heating (CH)
”
“
Domestic Hot Water (DHW)
”
“
Information
”
“
Settings
”
and selecting "Maintenance" using the
▲
/
▼
arrows
“
Information
”
“
Service
”
The menu also shows the hours from the last maintenance activity
performed and access to a log that lists the dates of the last 15 main-
tenance activities.
“
Service
”
“
Service history
”
“
Burn hours since last service
”
“
Burn hours till service
”
“
Reset Service Reminder
”
The “Settings”
→
“Boiler set.”
→
”Maintenance” menu contains the
advanced controls for this function, which, in any case, are only avail-
able if you access it with the manufacturer password. If it is necessary
to use this access level, contact the Technical Assistance Centre.