SYSTEM MANAGER
106
Register
number
Access Descrip-
tion
Note
Auto-
matic
conver-
sion
Value
range
510
X X
Minimum
value
that
can be
assigned
to the
heating
set-point
(Par. 23)
NV
Yes
Depends
on °C/°F
units
511
X X
Night-
time
attenua-
tion (Par.
28)
NV
Yes
Depends
on °C/°F
units
512
X X
Extra
primary
setpoint
for DHW
(Par. 38)
NV
Yes
Depends
on °C/°F
units
In the "Note" column, the registers marked with "V" can be written on
an ongoing basis (and be used for dynamic size control). Registers
marked with "NV", on the other hand, can be overwritten only for a lim-
ited number of times (around 10,000 times with an average of twice
a day).
Service reminder
Register
number
Access
Descrip-
tion
Automatic
conver-
sion
Value
range
L S
1500
X
Hours
elapsed
from the
last main-
tenance
activity
0…65534
hours
1501
X
Hours from
the next
mainte-
nance
activity
.. 0…main-
tenance
intervals
1504
X
Counter
delay index
0…14
1505
X
Delay
counter 0
0…65534
hours
1506
X
Delay
counter 1
0…65534
hours
1507
X
Delay
counter 2
0…65534
hours
Register
number
Access
Descrip-
tion
Automatic
conver-
sion
Value
range
L S
1508÷1518
X
Delay
counter
3÷13
0…65534
hours
1519
X
Delay
counter 14
0…65534
hours
1540
X
X
Service
reminder
reset
0...1 (1=re-
set)
1541
X
X
Setting the
hour count-
ing mode
for logs
33000-
33001
0= burner
ON hours
counted
1= boiler
ON hours
counted
1542
X
X
Mainte-
nance
interval
hours
0..25500
hours (in
steps of
100)
Note: If a counter shows the value 65535, this means that either it
is inactive or has exceeded the limit value.