3.1.7 Thermal module information
In order to display key information on the screen, press the menu key
and select "Information" with the
▲
/
▼
keys.
“
Menu
”
“
Central Heating (CH)
”
“
Domestic Hot Water (DHW)
”
“
Information
”
“
Settings
”
Press the
●
key to confirm.
The following screen will be displayed:
“
Information
”
“
Software Versions
”
“
Boiler Status
”
“
Boiler History
”
“
Error Log
”
By selecting "Boiler status" and pressing the
●
button you have the
following screen:
“
Boiler Status
”
“
Boiler
”
“
Managing
”
At this point by selecting "Master" or "Dep1 ... N" the following values
are displayed:
- Delivery temperature
- Return temperature
- DHW temperature (the sensor must be connected in order
to display a value; if it is not present, the default value is dis-
played)
- Outdoor temperature
- Flue gas temperature
- System temperature (the sensor must be connected in order
to display a value; if it is not present, the default value is dis-
played)
- Fan speed
- Ionization
- State
- Error
b
The display shows four lines at a time. You can scroll the list by
using the
▲
/
▼
keys.
“
Boiler Status
”
“
Flow Temperature
”
46.0
“
°C
”
“
Return Temperature
”
43.0
“
°C
”
“
DHW Temperature
”
44.0
“
°C
”
“
Outside Temperature
”
10.0
“
°C
”
By selecting "Boiler Register" and pressing the
●
button you have the
following screen:
“
Boiler History
”
“
Boiler
”
“
Managing
”
At this point by selecting "Master" or "Dep1 ... N" the following values
are displayed:
- Firing OK
- No firing
- No flame det.
- Oper. days
- Heat. burner hours
- DHW burner hours
“
Boiler History
”
“
Successful Ignitions
”
0
“
Failed Ignitions
”
1
“
Flame Failures
”
1
“
Operation Days
”
1
“
days
”
You can scroll the list by using the
▲
/
▼
keys.
By selecting "Error log" and pressing the
●
key, the following values
are displayed:
- Error log (the errors listed in paragraph “Manual error list" are
displayed)
- Error filter (in the "Error filter" item, it is possible to select: Disa-
bled - Vol. Err. - Block)
- Boiler ID filter (in the boiler ID filter item you can choose be-
tween: Disabled - Master - Dep1 ... N)
- Erase Error Log (allowed only with Installer password)
“
Error Log
”
“
Error Log
”
“
Filter Error Type
”
“
Disabled
”
“
Clear Error Log
”
You can scroll the list by using the
▲
/
▼
keys.