7.2 Temporary or short-term shut-down
In the event of temporary or short-term shut-down (e.g. due to holi-
days), proceed as follows:
- Press the MENU key and select with keys
▲
/
▼
"Time sched-
ule", confirm with key
●
.
- Select with keys
▲
/
▼
"Holiday Schedule” and confirm with
key
●
.
“
Clock Program
”
“
Program Group
”
“
Burn hours till service
”
“
Reset Service Reminder
”
“
Holiday Settings
”
- Select with keys
▲
/
▼
"Mode" and confirm with key
●
. Select
“System” mode and confirm.
“
Holiday Settings
”
“
Mode
”
“
System
”
“
Holiday Setpoint
”
“
Comfort
”
“
Begin Date
”
“
Saturday
”
01-08-2015
“
End Date
”
“
Saturday
”
01-08-2015
- Select with keys
▲
/
▼
"Holiday Setpoint" and confirm with key
●
.
- Select “Antifreeze” holiday setpoint and confirm.
“
Holiday Settings
”
“
Mode
”
“
System
”
“
Holiday Setpoint
”
“
Anti Fr
”
“
Begin Date
”
“
Saturday
”
01-08-2015
“
End Date
”
“
Saturday
”
01-08-2015
7.3 Preparing for extended periods of
disuse
The following operations shall be necessary if the Modular system is
not used for a long period of time:
- turn the main switch of the thermal modules and the main sys-
tem switch to "off"
- Close the fuel and water valves for the heating and domestic
hot water system.
b
Empty the thermal and sanitary system if there is a danger of
frost.
7.4 Cleaning
Use a cloth damped in soapy water to clean the boiler’s external cas-
ing.
To remove stubborn marks, use a cloth damped in a 50% mix of wa-
ter and denatured alcohol or a suitable cleaning product.
Carefully dry after cleaning.
a
Do not use abrasive cleaning pads or powder detergents.
a
Never clean the boiler without first disconnecting it from the
mains electricity supply by turning the mains power switch and
the control panel switch OFF.
b
The combustion chamber and flue pipes must be cleaned pe-
riodically by the manufacturer’s Technical Assistance Centre
or by a qualified heating engineer.
7.5 Maintenance
Please remember that THE PERSON RESPONSIBLE FOR SYSTEM
MANAGEMENT MUST ENSURE THAT PROFESSIONALLY QUAL-
IFIED HEATING ENGINEERS UNDERTAKE PERIODIC MAINTE-
NANCE AND COMBUSTION EFFICIENCY MEASUREMENTS.
B
’s Technical Assistance Centre is qualified to satisfy these legal
requirements and can also provide useful information on MAINTE-
NANCE PROGRAMMES designed to guarantee:
- Greater safety
- Compliance with applicable legislation
- Freedom from the risk of fines in the event of spot checks.
Regular maintenance is essential for the safety, efficiency and dura-
bility of the boiler.
Servicing is a legal requirement and must be performed at least once
a year by a professionally qualified heating engineer.