59
Section 3 - Programming from PC
Figure 3.9- Partitions Page
Partitions Page
This section describes the Partitions page (see Figure 3.9).
Partitions Table
No.
- This column shows the
Partition
ID number
that will be used instead of
the Partition label (Description), in some parts of the application.
Description
- This field is for the Partition label (maximum 16 characters). The
Application will use the label as the Partition ID.
Exit Time
- This parameter determines the Exit delay time (expressed in
minutes). Violation of ‘Delayed’ Zones during the Exit time will not provoke
Alarms. The Exit Time will start when the Partition arms, and will be signalled
by:
Activation of the Partition OC Outputs (programmed with the ‘Exit
Time’ signal);
A series of single beeps (emitted at one-second intervals) on all the
Partition Keypads (Mute keypads will not emit this signal);
A series of double beeps (emitted at one-second intervals) on all the
Partition PROXI Readers, the ‘Chime on PROXI Reader’ option must be
enabled otherwise, the PROXI Readers will not emit this signal (refer to
‘Options Page’).
Entry Time
- This parameter determines the duration (expressed in minutes)
of the Audible signal which will be generated when a ‘Delayed’ Zone of an
Содержание KYO 32 M
Страница 1: ...0 1 7 167 7 21 0 18 ...
Страница 10: ...10 Multifunction Control Panel The NC2 TAST LED Keypad Figure 1 3 The NC2 TAST LED Keypad D D ...
Страница 11: ...11 Section 1 Identification of Parts The ICON KP LED Keypad Figure 1 4 The ICON KP LED Keypad D D ...
Страница 12: ...12 Multifunction Control Panel Ö Ö Ö Ö 0 1 01 2 3 42 2 1 0 4 01 1 1 5 675 8 5 68 65 8 5 9 5 8 04 04 1 1 1 04 ...
Страница 71: ...71 Section 3 Programming from PC 5 11 6 0 1 2 3 1 4 3 3 5 2 3 0 1 2 3 ...
Страница 88: ...ISTISBLEUNKYO 2 6 160108 P70 17 6 85 7 6 U O 01 02 5HF FOLQ LQ RU WLRQ ...