Section 3 - Programming from PC
Monostable Times
This section describes how to set the
ON
and
OFF
Times of
Monostable
Outputs. Accepted values: 0 through 250 seconds.
To used this function, click on "Monostable" check-box.
The
ON Time
determines the time an Output will remain active.
The
OFF Time
determines the time an Output will remain in ‘forced’
standby status after expiry of its programmed
ON
Time
.
An Output will hold ‘forced’ standby status (even after its programmed
OFF
Time
) until the event which generated its activation clears.
Signals
NOTE:
The ‘
Restoral
’ conditions described in this section refer to
‘NON-
Monostable’
Outputs. Under normal circumstances, an Output will restore to
standby when its programmed
ON
Time
expires (refer to ‘
Monostable
’ and the
respective Table)
NOTE: The text in brackets appears on the Installer Menu.
z
Away Arm (Away Arm)
- The Output will activate when at least one of its
Partitions arms in Away mode.
z
Partitions Disarmed (Disarmed)
- The Output will activate when one of
its Partitions disarms.
z
Trouble (Warning)
- The Output will activate when a Trouble event occurs
(refer to the
‘Events Page’
section), with the exception of the ‘Telephone
Line Trouble’. The Output will restore automatically when the Trouble
clears.
This signal is for Non-Monostable Outputs only.
z
Alarm Memory (AlarmMem)
- The Output will activate when Alarms are
present in the memory. The Output will restore when the memory resets (via
a
‘Clear Alarm Memory’
command).
z
Exit Time (Exit T.)
- The Output will activate when the ‘
Exit Time
’ of its
assigned Partitions is triggered, and will remain active until the ‘
Exit Time
’
expires.
z
Entry Time (Entry T.)
- The Output will activate when ‘
Entry Time
’ of its
assigned Partitions is triggered, and will remain active until the ‘
Entry Time
’
expires.
z
Chime (Chime)
- The Output will activate when a ‘Chime’ zone is vio-
lated during disarmed status of one (or more) of its assigned Partitions. The
Output will remain active for approximately 1 second.
This signal is for
Monostable Outputs only.
z
Auto-Arm Timeout (Alert T.)
- The Output will activate at the pro-
grammed time, and will remain active during the countdown to automatic
arming.
Содержание KYO 32 M
Страница 1: ...0 1 7 167 7 21 0 18 ...
Страница 10: ...10 Multifunction Control Panel The NC2 TAST LED Keypad Figure 1 3 The NC2 TAST LED Keypad D D ...
Страница 11: ...11 Section 1 Identification of Parts The ICON KP LED Keypad Figure 1 4 The ICON KP LED Keypad D D ...
Страница 12: ...12 Multifunction Control Panel Ö Ö Ö Ö 0 1 01 2 3 42 2 1 0 4 01 1 1 5 675 8 5 68 65 8 5 9 5 8 04 04 1 1 1 04 ...
Страница 71: ...71 Section 3 Programming from PC 5 11 6 0 1 2 3 1 4 3 3 5 2 3 0 1 2 3 ...
Страница 88: ...ISTISBLEUNKYO 2 6 160108 P70 17 6 85 7 6 U O 01 02 5HF FOLQ LQ RU WLRQ ...