49
Section 3 - Programming from PC
Type
This section describes how the various Zone types respond to violation during
Standby status (Unbypassed). Bypassed zones will ignore violation and will not
generate Alarms.
In this section, the text in brackets
( ... )
refers to the text which will actually
appears on the LCD Keypad.
z
Instant (Instant)
- Violation of this type of zone will generate an Instant Alarm.
z
Delayed (Delayed)
- Violation of this type of zone will not generate an
Alarm during the Exit Time. Violation during Armed status (after the Exit
Time has elapsed) will generate an Alert signal (Entry-Time signal). If the
system is not disarmed before the Entry-Time elapses, the zone will gener-
ate an Alarm.
z
Path (Path)
- If this type of zone is the first zone to be violated, it will
generate an Instant Alarm. Path zones will not generate Alarms during
Entry and Exit times.
z
24 h (24 hours)
- This type of zone will always be active, regardless of the
Armed/Disarmed status of its Partition. Violation will generate an Instant
Alarm.
z
Duress (Duress)
- This type of zone is automatically programmed as a
Silent 24h zone. Duress zones activate the Communicator only, and are
suitable for Panic buttons.
z
Fire (Fire)
- This type of zone is automatically programmed as a 24h N.O.
(Normally Open) zone.
z
Switching (Switch.)
- This type of zone is automatically programmed as
a ‘Command Zone’. Violation of this type of zone will switch the status of
all the Partitions it is assigned to (from Away to Stay Arming or vice-
versa).
z
Arm (Arm Only)
- This type of zone is automatically programmed as a
‘Command Zone’. Violation of this type of zone will Arm all the Partitions
it is assigned to.
You cannot assign any attributes to ‘Command Zones’ (refer to the ‘Attributes’
section).
A
The IMQ-SECURITY SYSTEM approval applies only when command
zones are dedicated to command devices with the same Performance level as the
Control panel which houses the decoding circuit.
Balancing
z
Double Balancing (DBAL)
- In Standby status, the zone must be con-
nected to Negative by two 10K
Ω
resistors
(for Kyo16D the value of this
resistors is 1.2Kohm)
. If one of the resistors disconnects, the Control panel
will generate a Zone Alarm. In all other cases (Zone Open) the Control panel
will generate a Tamper event. This Type of connection (by means of just 2
Command Zones
Alarm Zones
(...)
Содержание KYO 32 M
Страница 1: ...0 1 7 167 7 21 0 18 ...
Страница 10: ...10 Multifunction Control Panel The NC2 TAST LED Keypad Figure 1 3 The NC2 TAST LED Keypad D D ...
Страница 11: ...11 Section 1 Identification of Parts The ICON KP LED Keypad Figure 1 4 The ICON KP LED Keypad D D ...
Страница 12: ...12 Multifunction Control Panel Ö Ö Ö Ö 0 1 01 2 3 42 2 1 0 4 01 1 1 5 675 8 5 68 65 8 5 9 5 8 04 04 1 1 1 04 ...
Страница 71: ...71 Section 3 Programming from PC 5 11 6 0 1 2 3 1 4 3 3 5 2 3 0 1 2 3 ...
Страница 88: ...ISTISBLEUNKYO 2 6 160108 P70 17 6 85 7 6 U O 01 02 5HF FOLQ LQ RU WLRQ ...