Multifunction Control Panel
The ‘Vibration’ and ‘Roller Blind’ attributes can be assigned to the first
6 Control panel zones only
(all zones for Kyo4 and only on the first 2
zones for Kyo16D).
z
Wireless (Wireless)
- (
Only for
8W
,
8GW
,
16D, 32
and
32G models
)
.
Only systems with a duly enabled VRX32-433
or Vector/RX8
Receivers
(refer to ‘Options’ in this section) can manage zones with this attribute.
The 6 digit Serial Numbers of devices connected to these zones must be
specified in the respective column. If a zone is setup as a
Wireless
zone,
the
Supervisory
attribute will be enabled automatically (refer to ‘
Supervi-
sory
’), and it will be shown in red.
IMPORTANT - If the “Low Battery” fault warning persists after the
batteries have been changed, deselect the “Wireless” attribute of the
respective zone then re-select it immediately.
z
Supervisory (Superv.)
- If a zone is setup as a
Wireless
zone, this at-
tribute will be enabled automatically, thus allowing the
VRX32-433 or Vector/
RX8
Receiver to monitor the Wireless device that is connected to the zone
(refer to ‘Supervisory Time’ on the ‘Partitions’ page). If the Wireless device
fails to send a signal to the
VRX32-433 or Vector/RX8
Receiver within the
programmed
Supervisory window
, the Control panel will generate a ‘Miss-
ing Device’ event.
The Identifier number of the zone which generated the event will be
recorded in the Event logger.
z
Double (Double P)
- A Zone with this attribute will generate an Alarm if it
is violated twice within the programmed time (accepted values: 0 through
250 seconds). Refer to the
‘Double Pulse’
.
z
Or (Or)
- Violation of a Zone with this attribute will generate an Alarm
even when only ONE of its Partitions is Armed.
z
And (And)
- Violation of a Zone with this attribute will generate an Alarm
only when all the
‘And’
Zones of the Partition concerned are violated
within the programmed Time (refer to ‘
T. And Zone
’ on the Partitions
page).
Cycles
This parameter determines the number of times the zone will signal the ‘Zone
Alarm’ event.
z
Repetitive (RP)
- Zones with this attribute will generate the ‘Zone Alarm’
event for an unlimited number of times.
z
Cycles (Cycles)
- The required number of Alarm cycles (0 through 14) can
be programmed in this field. If zero (0) is programmed, the zone will be
unable to generate Zone Alarm event.
Содержание KYO 32 M
Страница 1: ...0 1 7 167 7 21 0 18 ...
Страница 10: ...10 Multifunction Control Panel The NC2 TAST LED Keypad Figure 1 3 The NC2 TAST LED Keypad D D ...
Страница 11: ...11 Section 1 Identification of Parts The ICON KP LED Keypad Figure 1 4 The ICON KP LED Keypad D D ...
Страница 12: ...12 Multifunction Control Panel Ö Ö Ö Ö 0 1 01 2 3 42 2 1 0 4 01 1 1 5 675 8 5 68 65 8 5 9 5 8 04 04 1 1 1 04 ...
Страница 71: ...71 Section 3 Programming from PC 5 11 6 0 1 2 3 1 4 3 3 5 2 3 0 1 2 3 ...
Страница 88: ...ISTISBLEUNKYO 2 6 160108 P70 17 6 85 7 6 U O 01 02 5HF FOLQ LQ RU WLRQ ...