Your new Belle Group Masonry Saw is warranted to the original purchaser for a period of one-year (12 months) from the original date
of purchase. The Belle Group warranty is against defects in design, materials and workmanship.
The following are not covered under the Belle Group warranty:
1. Damage caused by abuse, misuse, dropping or other similar damage caused by or as a result of failure to follow assembly,
operation or user maintenance instructions.
2. Alterations, additions or repairs carried out by persons other than Belle Group or their recognised agents.
3. Transportation or shipment costs to and from Belle Group or their recognised agents, for repair or assessment against a
warranty claim, on any machine.
4. Materials and/or labour costs to renew, repair or replace components due to fair wear and tear.
The following components are not covered by warranty.
·
Drivebelt/s
· Engine air fi lter
· Engine spark plug
Belle Group and/or their recognised agents, directors, employees or insurers will not be held liable for consequential or other
damages, losses or expenses in connection with or by reason of or the inability to use the machine for any purpose.
Warranty Claims
All warranty claims should fi rstly be directed to Belle Group, either by telephone, by Fax, by Email, or in writing.
For warranty claims:
Tel: +44 (0)1538 380000
Fax: +44 (0)1538 380038
Email : [email protected]
Write to:
Belle Group Warranty Department,
Unit 5, Bode Business Park,
Ball Haye Green,
Leek,
Staffordshire, ST13 6BW
England.
Warranty
GB
Blade Fitting
GB
1. Remove the HT lead from the spark plug.
2. Expose the Arbor Shaft Bolt (9-12027) and Flange (948-05400) by raising the
Blade Protection Plate
(A) (Figure 1 & 2)
3. Remove the Arbor Shaft Bolt and Outer Flange
4. Check the Outer Flange and Arbor Shaft (948-04700) for damage or wear.
Replace if necessary, and fi t the blade as laid down in the safety codes USA
ANSI B7.1, Canada SCA and Great Britain HMSO No. 4.
5. Clean the Outer Flange before mounting the blade onto the Arbor Shaft and
Blade Pin (71.0.088).
6. Ensure that the arrow on the blade points in the same direction as the rotation
arrow of the blade guard.
7.
Re-fi
t
the
Outer
Flange.
8. Tighten the Arbor Shaft Bolt and secure fi rmly.
9. Lower the Blade Protection Plate.
10. Reconnect the HT lead to the spark plug.
11. The machine is now ready to be used.
CAUTION
Incorrect fi tting of a blade can cause serious injury. Ensure that the fi tting instructions are followed. If in
any doubt, Contact your supervisor or Belle Group.
A
A
Figure 1
Figure 2
Arbor Shaft
500mm Blade
Outer Flange
Bolt