44
Installation BRS20/22/30/32/40/42/50/52
Release 06 03/2020
For the supply voltage to be connected, perform the following steps:
Remove the terminal connector from the device.
Connect the wires according to the pin assignment on the device with
the clamps.
Fasten the wires in the terminal block by tightening the terminal
screws.
Mount the terminal block on the device using screws.
2.4.2
Signal contact (optional)
Figure 14: (1) Connection on the device, (2) terminal block mounted on the device
(front view), tightening torque, (3) terminal block mounted on the device
(view from above).
Proceed as follows:
Connect the signal contact lines with the terminal block connections.
Fasten the wires in the terminal block by tightening the terminal screws.
Mount the terminal block on the device using screws.
Without using PoE or
PoE+:
DC voltage
Rated voltage range DC:
24 V DC ... 48 V DC
+
Plus terminal of the supply
voltage
Voltage range DC incl.
maximum tolerances:
19 V DC ... 60 V DC
-
Minus terminal of the supply
voltage
Type of the voltages
that can be
connected
Specification of the supply
voltage
Pin assignment
Table 10: Supply voltage with characteristic value P: type and specification of the
supply voltage, pin assignment
4.4 lb-in
0.5 Nm
RELAY
1
2
3
Содержание HIRSCHMANN BRS20