Installation BRS20/22/30/32/40/42/50/52
Release 06 03/2020
41
2.4
Connecting the terminal blocks
2.4.1
Power supply
Note:
The supply voltage is connected to the device casing through
protective elements exclusively.
Supply voltage with characteristic value T
Figure 12: (1) DC voltage connection on the device, (2) terminal block mounted on
the device (front view), tightening torque, (3) terminal block mounted on
the device (view from above).
For the supply voltage to be connected, perform the following steps:
Remove the terminal connector from the device.
Connect the wires according to the pin assignment on the device with
the clamps.
Type of the voltages
that can be
connected
Specification of the supply
voltage
Pin assignment
DC voltage
Rated voltage range DC:
12 V DC ... 24 V DC
Voltage range DC incl.
maximum tolerances:
9.6 V DC ... 32 V DC
+24 V Plus terminal of the supply
voltage
0 V
Minus terminal of the supply
voltage
Table 7:
Supply voltage with characteristic value T: type and specification of the
supply voltage, pin assignment
+24 V(P1)
+24 V(P2)
0V 0V
+
+
-
-
12 V DC ... 24 V DC
12 V DC ... 24 V DC
4.4 lb-in
0.5 Nm
1
2
3
RELAY
Содержание HIRSCHMANN BRS20
Страница 87: ...Installation BRS20 22 30 32 40 42 50 52 Release 06 03 2020 87 ...
Страница 88: ......